14,419 posts · Joined 2002

#2 ·



Quote:
Originally Posted by gxxrgehk  /t/1468692/help-technics-sl-1210mk2-forgot-to-set-from-110v-to-220v#post_23214124

Technics SL-1210MK2 forgot to set from 110v to 220v.

I turned on with 110v and a blue light flashed once.

Suddenly I remembered wrong voltage and switched off the power at once.

Since than I can't turn it on.

What can I do?

Find a qualified service tech and pay him to do his thing.

12 posts · Joined 2006

#3 ·

It's there any internal fuse that blown up and need to replace?

10,401 posts · Joined 2002

#4 ·

IIRC the unit doesn't have internal fuse, the transformer may be blown.

12 posts · Joined 2006

#5 ·

On manual there is a fuse, right,

How can I access it and replace it?
technics_sl12xx_service_manual.pdf 2628k .pdf file
technics_sl12xx_service_manual_P.26.pdf 283k .pdf file

Attachments

  • 283.1 KB Views: 207

  • 2.6 MB Views: 350

10,401 posts · Joined 2002

#6 ·

You should be able just to unscrew the bottom of the turntable and find those fuses on the daughter board closest to the voltage switch. See which one that's blown and just pull that one and replace it with another with the same value and fast-blow variety.